StorageWorks SCSI Buses
5.6 Multiple SBB Shelves with a Single SCSI Bus
5.6 Multiple SBB Shelves with a Single SCSI Bus
Use the following procedure to configure two SBB shelves with seven devices on
one SCSI bus, as shown in Figure 5–5:
Note
The maximum number of SBB shelves on a single SCSI bus is two. A
maximum of seven storage SBBs can be installed in both shelves.
1. Turn off the shelf power by disconnecting the power cable from the shelf
power SBBs.
2. Remove the blowers as described in Section 3.2.
3. Discharge any static buildup by momentarily touching a finger to a blank
space on the backplane.
4. Make sure that the SHELF_OK jumpers are installed correctly on either the
backplane or on both the terminator board and the jumper board as described
in Chapter 2.
5. On the upper shelf, install the BA35X–MC jumper board in the backplane
connector behind slot 5.
6. On the lower shelf, install the BA35X–MC jumper board in the backplane
connector behind slot 5.
7. On the lower shelf, install the BA35X–MB terminator board in the backplane
connector behind slot 1.
8. Connect a BN21H-0E SCSI cable between the lower connector on the upper
shelf and the upper connector on the lower shelf.
9. Ensure that each device has a different SCSI bus address.
10. Replace the blowers as described in Section 3.2.
11. Turn on the power and verify that all the devices are active.
Figure 5–5 Single SCSI Bus on Two SBB Shelves
CXO-3598B-MC
7-DEVICE BUS INPUT
J
0123456
POWER
OUT
IN
SHELF 1
SHELF 2
J
0123456
POWER
T
JA1
JB1
BUS LENGTHS:
SHELF 1: 0.9 m (35.7 in)
SHELF 2: 0.9 m (34.7 in)
CABLE: 0.5 m (19.7 in)
TOTAL: 2.3 m (90.1 in)
JA1
JB1
(7)
(7)
StorageWorks SCSI Buses 5–9