Zobrazit stránku 28
StorageWorks Status Reporting
2.3 Storage SBB Status
Table 2–4 defines the valid states for these LEDs.
Table 2–4 Storage SBB Status LEDs
LED Status Indication
Device activity
Device fault
On
Off
SBB is operating normally.
Device activity
Device fault
Flashing
Off
SBB is operating normally.
Device activity
Device fault
Off
Off
SBB is operating normally.
The SBB is inactive, and there is no fault.
Device activity
Device fault
On
On
Fault status
SBB is probably not responding to control signals.
It is recommended that you replace the SBB.
Device activity
Device fault
Off
On
Fault status
SBB is inactive and spun down.
It is recommended that you replace the SBB.
Device activity
Device fault
On
Flashing
Fault status
SBB is active and is spinning down because of the
fault.